SHIPPING 10.99 ANY SIZE ORDER* We Love telephone Orders    1-800-800-5500

• Login • Your Account

  • View Cart (0)
  • Checkout
1-800-800-5500
Menu label
  • Manufacturer
      • Altronix
      • Automationsource
      • Edwards Signaling
      • Fire Lite Alarms
      • Genesis Cable (Honeywell)
      • GRI
      • Hid Global
      • Linear Corp
      • Mier Products
      • Optex
      • Potter Electric
      • Preferred Technology
      • Safety Technology
      • Silent Knight
      • System Sensor
  • Categories
      • Access Control
      • Audio Video
      • catv outdoor
      • Commercial AV
      • Fire Protection Equipment
      • Hardware Tools
      • Intrusion Products
      • Video Surveillance
      • Wire
  • Shipping
  • Customer Service
  • Contact
  • Company Info
    • My Account
    • Availability
    • Login
Altronix → Altronix MAXIMAL33FV 2-eflow6nbv 2-acm8 220v
Altronix  MAXIMAL33FV
rganization

Altronix MAXIMAL33FV 2-eflow6nbv 2-acm8 220v

Special Price: $621.11
SKU: AX-MAXIM33FV
LimitedAvailability
MPN: MAXIMAL33FV
Email this product to a friend
  • Description
  • Reviews

Maximal33FV

Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, Dual 12/24VDC P/S @ 6A each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

Maximal33FV Access Power Controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.

Input
220VAC (working range 198VAC - 256VAC), 50/60Hz, 4.2A input.
Power supply input options:
a) Two (2) common power input for either ACM8 and lock power (factory installed).
b) Two (2) isolated power inputs (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A total.
Sixteen (16) Access Control System trigger inputs.
Input options:
a) Sixteen (16) normally open (NO) inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
Output
12VDC and/or 24VDC outputs.
Maximum output current Options:
A) 12VDC @ 5.3A plus 12VDC @ 5.3A.
B) 12VDC @ 5.3A plus 24VDC @ 5.6A.
C) 24VDC @ 5.6A plus 24VDC @ 5.6A.
Sixteen (16) independently controlled outputs.
Output options:
a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
b) Sixteen (16) form "C" 5A rated relay outputs.
c) Any combination of the above.
Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5A).
Filtered and electronically regulated outputs (built-in power supply).
Thermal and short circuit protection with auto reset.
Fuse Ratings
Power Supply input fuse rated @ 5A/250V.
ACM8 boards main fuse is rated at 10A. Fused outputs are rated @ 2.5A each.
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 2 hours.
Low battery and battery presence supervision (form "C" contact).
Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Electrical
Temperature:
Operating: 0 ° C to 49 ° C (32 ° F to 120 ° F).
Storage: - 20 ° C to 70 ° C ( - 4 ° F to 158 ° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
12VDC: 65 BTU/Hr.
24VDC: 138 BTU/Hr.
12VDC and 24VDC: 101 BTU/Hr.
System AC input VA requirement: 924VA.
  Compare Print


Customer Reviews

(0.00) stars out of 5
# of Ratings: 0
(Only registered customers can rate)
  • Customer Service
  • Contact Us
  • Order Tracking
  • Wishlist
  • Your Account
  • Store Policies & Info
  • Shipping
  • Returns
  • FAQs
  • Privacy Policy
  • Security
  • Helpful Links
  • About Us
  • Payment Methods
  • Powered by AspDotNetStorefront
© Automationsrouce.com 2025. All Rights Reserved. Powered by AspDotNetStorefront

Shopping Cart: 0 Items

Your shopping cart is currently empty.
Discounts:
Total: $0.00
Loading...