Altronix → Altronix MAXIMAL55D 12vdc@20a 16ptc out
rganization

Altronix MAXIMAL55D 12vdc@20a 16ptc out

Special Price: $580.16
SKU: AX-MAX55D
LimitedAvailability
MPN: MAXIMAL55D
Email this product to a friend
  • Description
  • Reviews

Maximal55D

Access Power Controller w/ Power Supply/Chargers, 16 PTC Class 2 Relay Outputs, Dual 12VDC P/S @ 9.5A each, 115VAC, BC800 Enclosure

Maximal55D distributes and switches power to access control systems and accessories. Unit converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC Class 2 Rated PTC protected power-limited outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.

  • Input
    • 115VAC 60Hz, 5.2A input.
      • Power supply input options:
        • a) Two (2) common power input for either ACM8CB and lock power (factory installed).
        • b) Two (2) isolated power inputs (external power supply is required), (current is determined by the power supply connected, not to exceed a maximum of 10A total).
    • Sixteen (16) Access Control System trigger inputs.
      • Input options:
        • a) Sixteen (16) normally open (NO) inputs.
        • b) Sixteen (16) open collector inputs.
        • c) Any combination of the above.
  • Output
    • 12VDC outputs.
      • Maximum output current Options:
        • A) 12VDC @ 9.5A plus 12VDC @ 9.5A.
    • Class 2 Rated power limited outputs (auto-resettable).
    • Sixteen (16) independently controlled outputs can be Fail-Safe and/or Fail-Secure power outputs.
    • Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2A).
    • Filtered and electronically regulated outputs (built-in power supply).
    • Thermal and short circuit protection with auto reset.
  • Fuse Ratings
    • Power Supply input fuse rated @ 3.5A/250V.
    • ACM8CB boards main fuse is rated at 10A Output fuses are rated @ 2.5A.
  • Features
    • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
      • Fire Alarm disconnect input options:
        • a) Normally open (NO) or normally closed (NC) dry contact input.
        • b) Polarity reversal input from FACP signaling circuit.
    • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    • Low battery and battery presence supervision (form "C" contact).
  • Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
    • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Visual Indicators
    • Red LEDs indicate outputs are triggered (relays energized).
    • Green LED indicates FACP disconnect is triggered.
    • AC input and DC output LED indicators.
  • Electrical
      • Temperature:
        • Operating: 0 ° C to 49 ° C (32 ° F to 120 ° F).
        • Storage: - 20 ° C to 70 ° C ( - 4 ° F to 158 ° F).
    • Relative Humidity 85% +/- 5%.
    • BTU/Hr (approx.): 117 BTU/Hr.
    • System AC input VA requirement: 598VA.

Customer Reviews

(0.00) stars out of 5
# of Ratings: 0
(Only registered customers can rate)
  • Customer Service
  • Contact Us
  • Order Tracking
  • Wishlist
  • Your Account
  • Store Policies & Info
  • Shipping
  • Returns
  • FAQs
  • Privacy Policy
  • Security
  • Helpful Links
  • About Us
  • Payment Methods
  • Powered by AspDotNetStorefront
© Automationsrouce.com 2025. All Rights Reserved. Powered by AspDotNetStorefront

Shopping Cart: 0 Items

Your shopping cart is currently empty.
Discounts:
Total: $0.00
Loading...